File:Generations of district heating systems EN.svg
Archivo original (archivo SVG, nominalmente 1362 × 1003 píxeles, tamaño de archivo: 1,16 MB)
Leyendas
Resumen[editar]
DescripciónGenerations of district heating systems EN.svg |
Deutsch: Die Grafik zeigt die 4 verschiedenen Generation von Fernwärmesystemen samt ihren Wärmequellen English: In this picture the 4 different generations of district heating systems are shown, including the heat sources |
Fecha | |
Fuente |
Based on [1] and Henrik Lund et al: 4th Generation District Heating (4GDH): Integrating smart thermal grids into future sustainable energy systems. Energy 68, 2014, 1-11, doi:10.1016/j.energy.2014.02.089 |
Autor | |
Otras versiones |
|
SVG desarrollo InfoField | El código fuente de esta imagen SVG es válido. Este gráfico vectorial fue creado con Inkscape |
Text in SVG InfoField | Text in page as path, in addition outside of page as font/embedded for editing (reason: problems with font-rendering) |
Licencia[editar]
Este archivo está disponible bajo la licencia Creative Commons Dedicación de Dominio Público CC0 1.0 Universal. | |
La persona que ha asociado una obra a este documento lo dedica al dominio público mediante la cesión mundial de sus derechos bajo la ley de derechos de autor y todos los derechos legales adyacentes propios de dicha, en el ámbito permitido por ley. Puedes copiar, modificar, distribuir y reproducir el trabajo, incluso con objetivos comerciales, sin pedir aprobación del autor.
http://creativecommons.org/publicdomain/zero/1.0/deed.enCC0Creative Commons Zero, Public Domain Dedicationfalsefalse |
text[editar]
- Vorlauf
- Rücklauf
- Energieeffizienz
- 50-60°C (70°C) (Ultra-Niedrigtemperatur Fernwärme <50°C)
- ~25°C
- <70°C
- <100°C
- >100°C
- <45°C
- <200°C
- <80°C
- 1G / 1880-1930
- 4G / 2020-2050
- 3G / 1980-2020
- 2G / 1930-1980
- Entwicklung (Fernwärmegeneration) / Zeitraum Stand der Technik
- Fernwärmenetz
- Fernkältenetz
- Energieeffizienz /Temperaturlevel
- 1. Generation: Dampf
- Dampfbetriebenes System, Dampfleitungen in Betonführungen
- Heißwassersystem mit Druckleitungen, schwere Anlagenteile, große vor Ort errichtete Technik
- vorgedämmte Leitungen, Industrialisierte kompakte, Übergabestationen mit Wärmedämmung, Wärmezählung und Überwachung
- 4. Generation
- Niedriger Energiebedarf, Intelligentes Energiesystem (optimale Wechselwirkungen zwischen Energiequellen, Verteilung und Verbrauch), Zweiwegesystem
- 2. Generation: vor Ort errichtetes System
- 3. Generation: Vorgefertigtes System
- Dampfspeicher
- Kohle, Müll
- Nahwärme
- KWK Kohle, KWK Erdöl
- Solare Fernwärme
- Bioenergie, Bioenergie KWK
- KWK Müll, KWK Öl, KWK Kohle
- Heizwerke Müll, Öl, Kohle
- Müllheizkraftwerk KWK
- Potentielle zukünftige Energiequellen
- industrielle Biomassekonversion
- Fernwärme
- Industrieabwärme
- Rechenzentren
- Saisonale Wärmespeicher
- Geothermie
- Stromüberschüsse, Ökostrom
- 2-Wege-Nutzung, z.B. Supermarkt (Prosumer)
- Zentrale Fernkältewerke
- zentrale Großwärmepumpen
- Nutzung auch in Niedrigenergiehäusern (möglich)
- Kältespeicher
- Solare Fernwärme
- Wärmespeicher
- Bioenergie, KWK
- Biomass, CHP Biomass
- CHP waste, CHP oil, CHP coal
- Gas waste, Oil, Coal
- Future energy source
- Biomass conversion
- 2-way District Heating e.g. supermarket
- Centralised district cooling plant
- Centralised heat pump
- Coldstorage
- Industry surplus
- Heatstorage
- CHP Biomass
- CHP coal, CHP oil
- Steamstorage
- Local District Heating
- Data center
- Seasonal heat storage
- Geothermal
- PV, Wave, Wind surplus, Electricity
- CHP waste incineration
- Also low energy buildings
- Coal, Waste
- District Heating
- Large scale solar
- Development (District Heating generation) / Period of best available technology
- District heating grid
- District cooling grid
- Large scale solar
- Energy efficiency / temperature level
- 1G: STEAM
- Steam system, steam pipes in concrete ducts
- 2G: IN SITU
- Pressurised hot-water system, Heavy equipment, Large ”build on site” stations
- 3G: PREFABRICATED
- Pre-insulated pipes, Industrialised compact substations (also with insulation), Metering and monitoring
- 4G: 4th GENERATION
- Low energy demands, Smart energy (optimum interaction of energy sources, distribution and consumption), 2-way DH
- DH flow
- Energy efficiency
- 50-60°C (70°C) (ULTDH <50°C)
- ~25°C
- <70°C
- <100°C
- >100°C
- <45°C
- <200°C
- DH return
- <80°C
- 1G / 1880-1930
- 4G / 2020-2050
- 3G / 1980-2020
- 2G / 1930-1980
Historial del archivo
Haz clic sobre una fecha y hora para ver el archivo tal como apareció en ese momento.
Fecha y hora | Miniatura | Dimensiones | Usuario | Comentario | |
---|---|---|---|---|---|
actual | 17:23 12 jul 2018 | 1362 × 1003 (1,16 MB) | Mrmw (discusión | contribs.) | small changes | |
20:45 11 jul 2018 | 1362 × 1003 (191 kB) | Mrmw (discusión | contribs.) | {{Information |description ={{en|1=a}} |date = |source =a |author =a }} |
No puedes sobrescribir este archivo.
Usos del archivo
Las siguientes páginas usan este archivo:
Uso global del archivo
Las wikis siguientes utilizan este archivo:
- Uso en ca.wikipedia.org
- Uso en de.wikipedia.org
- Uso en en.wikipedia.org
- Uso en es.wikipedia.org
- Uso en fr.wikipedia.org
- Uso en it.wikipedia.org
- Uso en nl.wikipedia.org
- Uso en simple.wikipedia.org
- Uso en sv.wikipedia.org
- Uso en zh.wikipedia.org
Metadatos
Este archivo contiene información adicional, probablemente añadida por la cámara digital o el escáner usado para crearlo o digitalizarlo.
Si el archivo ha sido modificado desde su estado original, pueden haberse perdido algunos detalles.
Anchura | 384.43033mm |
---|---|
Altura | 283.01398mm |