File:Real-time MRI of a human heart (short-axis view).ogv
Real-time_MRI_of_a_human_heart_(short-axis_view).ogv (Ogg Theora video file, length 6.4 s, 463 × 463 pixels, 1.15 Mbps, file size: 895 KB)
Captions
DescriptionReal-time MRI of a human heart (short-axis view).ogv |
English: Real-time MRI of a human heart (short-axis view) at 1.5 mm spatial resolution and 33 ms temporal resolution. The T1-weighted images were acquired with an RF-spoiled radial FLASH sequence (TR/TE = 2.2/1.4 ms, flip angle 8°, 15 spokes) at 1.5 mm resolution, 8 mm section thickness, and 33 ms acquisition time without ECG or respiratory gating. Image reconstruction was achieved by regularized nonlinear inversion. (See: doi:10.1186/1532-429X-12-39 http://www.jcmr-online.com/content/12/1/39) |
Date | |
Source | doi:10.1186/1532-429X-12-39 |
Author | Shuo Zhang, Martin Uecker, Dirk Voit, Klaus-Dietmar Merboldt, Jens Frahm |
Permission (Reusing this file) |
This file is licensed under the Creative Commons Attribution 2.0 Generic license.
|
Contact:
Biomedizinische NMR Forschungs GmbH am Max-Planck-Institut für biophysikalische Chemie Am Fassberg 11 37077 Göttingen
Literature:
Martin Uecker, Shuo Zhang, Dirk Voit, Alexander Karaus, Klaus-Dietmar Merboldt, and Jens Frahm, Real-time magnetic resonance imaging at a resolution of 20 ms, NMR in Biomedicine 23: 986–994 (2010) DOI:10.1002/nbm.1585
File history
Click on a date/time to view the file as it appeared at that time.
Date/Time | Thumbnail | Dimensions | User | Comment | |
---|---|---|---|---|---|
current | 11:21, 29 May 2011 | 6.4 s, 463 × 463 (895 KB) | Marmau (talk | contribs) | {{Information |Description ={{en|1=Real-time MRI of a human heart (short-axis view) at 1.5 mm spatial resolution and 33 ms temporal resolution. The T1-weighted images were acquired with an RF-spoiled radial FLASH sequence (TR/TE = 2.2/1.4 ms, flip angl |
You cannot overwrite this file.
File usage on Commons
There are no pages that use this file.
Transcode status
Update transcode statusFile usage on other wikis
The following other wikis use this file:
- Usage on de.wikipedia.org
Metadata
This file contains additional information such as Exif metadata which may have been added by the digital camera, scanner, or software program used to create or digitize it. If the file has been modified from its original state, some details such as the timestamp may not fully reflect those of the original file. The timestamp is only as accurate as the clock in the camera, and it may be completely wrong.
Short title | Real-time CMR (short-axis view) at 1.5 mm spatial resolution and 33 ms temporal resolution. |
---|---|
Publisher | Biomedizinische NMR Forschungs GmbH |
Location depicted | |
Copyright holder | BiomedNMR 2010 |
Author | Zhang S, Uecker M, Voit D, Merboldt K-D, Frahm J. doi:10.1186/1532-429X-12-39 |
Usage terms | creative commons Attribution 2.0 Generic (CC BY 2.0) |
Software used | |
Contact information | Martin Uecker <muecker@gwdg.de> |