File:Electron-Tomography-of-Cryo-Immobilized-Plant-Tissue-A-Novel-Approach-to-Studying-3D-Macromolecular-pone.0106928.s006.ogv
Original file (Ogg Theora video file, length 8.3 s, 1,344 × 896 pixels, 27.96 Mbps, file size: 27.77 MB)
Captions
Summary[edit]
DescriptionElectron-Tomography-of-Cryo-Immobilized-Plant-Tissue-A-Novel-Approach-to-Studying-3D-Macromolecular-pone.0106928.s006.ogv |
English: The process of threshold segmentation in Amira, to obtain a segment map that include most of the electron-dense features above background noise for each slice, and rendering as a mesh surface for 3D visualization and further analyses. |
|||
Date | ||||
Source | Video S3 from Sarkar P, Bosneaga E, Yap E, Das J, Tsai W, Cabal A, Neuhaus E, Maji D, Kumar S, Joo M, Yakovlev S, Csencsits R, Yu Z, Bajaj C, Downing K, Auer M (2014). "Electron Tomography of Cryo-Immobilized Plant Tissue: A Novel Approach to Studying 3D Macromolecular Architecture of Mature Plant Cell Walls In Situ". PLOS ONE. DOI:10.1371/journal.pone.0106928. PMID 25207917. PMC: 4160213. | |||
Author | Sarkar P, Bosneaga E, Yap E, Das J, Tsai W, Cabal A, Neuhaus E, Maji D, Kumar S, Joo M, Yakovlev S, Csencsits R, Yu Z, Bajaj C, Downing K, Auer M | |||
Permission (Reusing this file) |
|
|||
Provenance InfoField |
|
File history
Click on a date/time to view the file as it appeared at that time.
Date/Time | Thumbnail | Dimensions | User | Comment | |
---|---|---|---|---|---|
current | 22:58, 10 December 2014 | 8.3 s, 1,344 × 896 (27.77 MB) | Open Access Media Importer Bot (talk | contribs) | Automatically uploaded media file from Open Access source. Please report problems or suggestions here. |
You cannot overwrite this file.
File usage on Commons
There are no pages that use this file.
Transcode status
Update transcode statusMetadata
This file contains additional information such as Exif metadata which may have been added by the digital camera, scanner, or software program used to create or digitize it. If the file has been modified from its original state, some details such as the timestamp may not fully reflect those of the original file. The timestamp is only as accurate as the clock in the camera, and it may be completely wrong.
Author | Sarkar P, Bosneaga E, Yap E, Das J, Tsai W, Cabal A, Neuhaus E, Maji D, Kumar S, Joo M, Yakovlev S, Csencsits R, Yu Z, Bajaj C, Downing K, Auer M |
---|---|
Usage terms | http://creativecommons.org/publicdomain/zero/1.0/ |
Image title | The process of threshold segmentation in Amira, to obtain a segment map that include most of the electron-dense features above background noise for each slice, and rendering as a mesh surface for 3D visualization and further analyses. |
Software used | Xiph.Org libtheora 1.1 20090822 (Thusnelda) |
Date and time of digitizing | 2014 |